Chapter 7 Specifications
7 - 3
(3)
Common specifications of 200 V class and 400 V class models (continued)
Model name (type name)
SJ700-XXXFF2.FEF2,FUF2
110
L/H
150
L/H
185
L/H
220
L/H
300
L/H
370
L/H
450
L/H
550
L/H
750
L/H
900
H
1100
H
1320
H
1600
H
Oper
ating
environment
Ambient
temperature,
storage
temperature(note5),
humidity
-10
°
C to +40
°
C (ambient), -20
°
C to +65
°
C (storage), 20% to 90% RH (no condensation allowed)
Vibration tolerance
(See Note 1.)
5.9m/s
2
(0.6G),10
~
55Hz 2.94m/s
2
(0.3G),10
~
55Hz
Installation
environment
Environment without corrosive gases and dust, at an altitude of 1,000 m or less Note9)
Coating color
Gray
Optional boar
ds
Feedback option
Vector control with sensor
Digital input option
4-digit BCD input, 16-bit binary input
DeviceNet option
Option to support the open-network DeviceNet function
LonWorks option
Option to support the open-network LonWorks function
Profibus-DP option Option to support the open-network Profibus-DP function
Other optional components
Braking resistor, AC reactor, DC reactor, noise filter, operator cables, Harmonic-wave suppressor unit,
LCR filter, analog operation panel, regenerative braking unit, controllers for various applications
Note 1: The vibration tolerance was tested in compliance with JIS C60068-2-6:2010 (IEC 60068-2-6:2007).
Note 2: The insulation distance complies with the UL and CE standards.
Note 3: The applicable motor refers to Hitachi standard 3-phase motor(4-pole).when using other motors,care must be taken to
prevent the rated motor current(50/60Hz)from exceeding the rated output current of the inverter.
Note 4: Function “64(EMR)”cannot be assigned to input terminal 3 by an operation from the operator. The function is automatically
assigned to the terminal when slide switch SW1 is set to ON.
Note 5: The storage temperature refers to the short-term temperature during transport.
Note 6: The frequency command will equal the maximum frequency at 9.8V for input voltage 0 to 10VDC,or at 19.8mA for input
current 4 to 20mA.If this characteristic is not satisfactory for your application, contact your Hitachi sales representative.
Note 7: The analog voltage monitor and the analog current monitor are rough output values for analog meter connection.
The maximum output value might shift a little by the difference of the analog output circuit than 10V or 20mA.
Please inquire when there is a possibility that the inconvenience is caused.
Note8:
As for the range of the speed change, the variation range is different according to the installation situation and the
characteristic and the usage condition of the motor. Please inquire about details.
Note9: The density of air decreases by 1% whenever rising by 100m when the altitude exceeds 1000m. Therefore, it is necessary to
decrease the calorific value.
The calorific value of the main circuit semiconductor such as IGBT is proportional to the current
and the voltage. Therefore, please decrease by 1% and use the current rating every time it rises by 100m.
Please inquire about use in the high ground of 2500m or more.
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...