Chapter 4 Explanation of Functions
4 - 136
Register
No.
Function name
Function
code
R/W
Monitoring and setting items Data resolution
Register
No.
1354h (Reserved)
-
-
Inaccessible
-
1355h
Start frequency adjustment
b082
R/W 10 to 999
0.01 [Hz]
1356h
Carrier frequency setting
b083
R/W 5 to 120 (5 to 80 :90 to 160kW)
0.1 [kHz]
1357h
Initialization mode (parameters
or trip history)
b084 R/W 0 (clearing the trip history), 1 (initializing the data), 2
(clearing the trip history and initializing the data)
-
1358h
Country code for initialization
b085
R/W 0 (Japan), 1 (EU), 2 (U.S.A.)
-
1359h
Frequency scaling conversion
factor
b086
R/W 1 to 999
0.1
135Ah STOP key enable
b087
R/W 0 (enabling), 1 (disabling), 2 (disabling only stop)
-
135Bh Restart mode after FRS
b088
R/W
0 (starting with 0 Hz), 1 (starting with matching
frequency), 2 (starting with active matching
frequency)
-
135Ch (Reserved)
-
-
Inaccessible
-
135Dh Dynamic braking usage ratio
b090
R/W 0 to 1000
0.1 [%]
135Eh Stop mode selection
b091
R/W 0 (deceleration until stop), 1 (free-run stop)
-
135Fh
Cooling fan control
b092
R/W
0 (always operating the fan), 1 (operating the fan only
during inverter operation [including 5 minutes after
power-on and power-off])
-
1360h (Reserved)
-
-
Inaccessible
-
1361h (Reserved)
-
-
Inaccessible
-
1362h
Dynamic braking control
b095
R/W
0 (disabling), 1 (enabling [disabling while the motor is
stopped]), 2 (enabling [enabling also while the motor
is stopped])
-
1363h
Dynamic braking activation level
b096
R/W 330 to 380, 660 to 760
1. [V]
1364h (Reserved)
-
-
Inaccessible
-
1365h
Thermistor for thermal protection
control
b098 R/W 0 (disabling the thermistor), 1 (enabling the thermistor
with PTC), 2 (enabling the thermistor with NTC)
-
1366h
Thermal protection level setting
b099
R/W 0. to 9999.
1. [
Ω
]
1367h
Free-setting V/f frequency (1)
b100
R/W 0. to "free-setting V/f frequency (2)"
1 [Hz]
1368h
Free-setting V/f voltage (1)
b101
R/W 0. to 8000
0.1 [V]
1369h
Free-setting V/f frequency (2)
b102
R/W 0. to "free-setting V/f frequency (3)"
1 [Hz]
136Ah Free-setting V/f voltage (2)
b103
R/W 0. to 8000
0.1 [V]
136Bh Free-setting V/f frequency (3)
b104
R/W 0. to "free-setting V/f frequency (4)"
1 [Hz]
136Ch Free-setting V/f voltage (3)
b105
R/W 0. to 8000
0.1 [V]
136Dh Free-setting V/f frequency (4)
b106
R/W 0. to "free-setting V/f frequency (5)"
1 [Hz]
136Eh Free-setting V/f voltage (4)
b107
R/W 0. to 8000
0.1 [V]
136Fh
Free-setting V/f frequency (5)
b108
R/W 0. to "free-setting V/f frequency (6)"
1 [Hz]
1370h
Free-setting V/f voltage (5)
b109
R/W 0. to 8000
0.1 [V]
1371h
Free-setting V/f frequency (6)
b110
R/W 0. to "free-setting V/f frequency (7)"
1 [Hz]
1372h
Free-setting V/f voltage (6)
b111
R/W 0. to 8000
0.1 [V]
1373h
Free-setting V/f frequency (7)
b112
R/W 0. to 400.
1 [Hz]
1374h
Free-setting V/f voltage (7)
b113
R/W 0. to 8000
0.1 [V]
1375h to
137Ah (Reserved) -
-
Inaccessible
-
1383h (Reserved)
-
-
Inaccessible
-
1384h (Reserved)
-
-
Inaccessible
-
1385h
Overvoltage suppression enable
b130
R/W 0 (disabling), 1 (enabling), 2 (enabling with
acceleration)
-
1386h
Overvoltage suppression level
b131
R/W 200 V class: 330 to 390 (V)
400 V class: 660 to 780 (V)
1 [V]
1387h
Acceleration and deceleration
rate at overvoltage suppression
b132
R/W 10 to 3000
0.01
[sec.]
1388h
Overvoltage suppression
propotional gain
b133
R/W 0 to 255
0.01
1389h
Overvoltage suppression Integral
time
b134
R/W 0 to 65535
0.001
[sec.]
1390h to
1400h
(Reserved) -
-
Inaccessible
-
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...