Chapter 4 Explanation of Functions
4 - 73
4.2.75 Reverse rotation signal (RVR)
The inverter continues to output the forward rotation (RVR)
signal while it is driving the motor for reverse operation.
The RVR signal is turned off while the inverter is driving the motor for forward operation or stopping the
motor.
Item
Function code
Data or range of data
Description
Terminal function
C021 to C025
52
RVR: Reverse rotation signal
Alarm relay terminal function
C026
4.2.76 Major failure signal (MJA)
The inverter outputs the major failure (MJA) signal in addition to
an alarm signal when it trips because of one of the errors listed
below.
(This signal function applies to the tripping caused by hardware.)
No.
Error code
Description
1 E10.*
CT
error
2 E11.*
CPU
error
3 E14.*
Ground-fault
protection
4
E20.*
Temperature error due to cooling-fan fault
5
E23.*
Gate array communication error
6
E25.*
Main circuit error
Item
Function code
Data or range of data
Description
Terminal function
C021 to C025
53
MJA: Major failure signal
Alarm relay terminal function
C026
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Related code
Output frequency (Hz)
Forward rotation signal
Reverse rotation signal
C021 to C025: Terminal [11] to [15] functions
C026: Alarm relay terminal function
Related code
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...