Chapter 4 Explanation of Functions
4 - 95
4.2.100 Torque LAD stop function
The torque LAD stop function is effective when "03" (sensorless
vector control) is specified for the V/F characteristic curve
selection (A044/A244). This function temporarily stops the
frequency-based deceleration function (LAD) when the torque
limitation function operates.
Item
Function code
Data or range of data
Description
V/F characteristic
curve selection
A044/A244 03
Sensorless vector control
Torque limit
selection
b040
00
Quadrant-specific setting mode
01 Terminal-switching
mode
02
Analog input mode
03
Option 1 mode
04
Option 2 mode
Torque limit (1)
b041
0 to 150 (%)
Forward powering (in quadrant-specific setting
mode)
Torque limit (2)
b042
0 to 150 (%)
Reverse regeneration (in quadrant-specific
setting mode)
Torque limit (3)
b043
0 to 150 (%)
Reverse powering (in quadrant-specific setting
mode)
Torque limit (4)
b044
0 to 150 (%)
Forward regeneration (in quadrant-specific
setting mode)
Torque limit
LADSTOP enable
b045
00
Disabling the torque LAD stop function
01
Enabling the torque LAD stop function
Terminal function
C001 to C008
40
Whether to enable torque limitation
41
Torque limit switch 1
42
Torque limit switch 2
A044/A244: V/F characteristic curve selection,
1st/2nd motors
b040: Torque limit selection
b041 to b044: Torque limits (1) to (4)
b045: Torque limit LADSTOP enable
Related code
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...