Chapter 4 Explanation of Functions
4 - 67
4.2.64 Over-torque signal (OTQ)
The inverter outputs the over-torque signal when it detects
that the estimated motor output torque exceeds the
specified level.
To enable this function, assign function "07" (OTQ:
over-torque signal) to an intelligent output terminal.
This function is effective only when the V/F characteristic curve selection selected with function "A044" or
"A244" is the sensorless vector control. With any other V/F characteristic curve selection, the output of the
OTQ signal is unpredictable.
When using the inverter for a lift, use the OTQ signal as the trigger to stop braking. Use the
frequency-arrival signal as the trigger to start braking.
Item
Function code
Set value
Description
Terminal function
C021 to C025
07
OTQ: Over-torque signal
Alarm relay terminal function
C026
Over-torque (forward-driving) level
setting
C055
0. to 150. (%)
Threshold level to output the OTQ signal
during forward powering operation
Over-torque (reverse
regenerating) level setting
C056
0. to 150. (%)
Threshold level to output the OTQ signal
during reverse regeneration operation
Over-torque (reverse driving) level
setting
C057
0. to 150. (%)
Threshold level to output the OTQ signal
during reverse powering operation
Over-torque (forward
regenerating) level setting
C058
0. to 150. (%)
Threshold level to output the OTQ signal
during forward regeneration operation
A044/A244/A344: V/F characteristic curve selection,
1st/2nd/3rd motors
C021 to C025: Terminal [11] to [15] functions
C055: Over-torque (forward-driving) level setting
C056: Over-torque (reverse regenerating) level setting
C057: Over-torque (reverse driving) level setting
C058: Over-torque (forward regenerating) level setting
Related code
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...