Chapter 4 Explanation of Functions
4 - 133
Register
No.
Function name
Function code
R/W
Monitoring and setting items Data resolution
Register
No.
12B0h
Operation-target frequency
selection 2
A142 R/W
0 (digital operator), 1 (keypad potentiometer), 2
(input via O), 3 (input via OI), 4 (external
communication), 5 (option 1), 6 (option 2), 7 (pulse
train frequency input)
-
12B1h Operator
selection
A143
R/W
0 (addition: A141 + A142), 1 (subtraction: A141 -
A142), 2 (multiplication: A141 x A142)
-
12B2h (Reserved)
-
- Inaccessible
-
12B3h
Frequency to be added
A145 (high)
R/W
0 to 40000
0.01 [Hz]
12B4h A145
(low)
R/W
12B5h
Sign of the frequency to be
added
A146 R/W
00 (frequency c A145), 01 (frequency
command - A145)
-
12B6h to
12B8h
(Reserved) -
-
Inaccessible
-
12B9h
EL-S-curve
acceleration/deceleration ratio 1
A150
R/W 0 to 50
1 [%]
12BAh
EL-S-curve
acceleration/deceleration ratio 2
A151
R/W 0 to 50
1 [%]
12BBh
EL-S-curve
deceleration/deceleration ratio 1
A152
R/W 0 to 50
1 [%]
12BCh
EL-S-curve
deceleration/deceleration ratio 2
A153
R/W 0 to 50
1 [%]
12BDh to
1300h
(Reserved) -
-
Inaccessible
-
Summary of Contents for L700 Series
Page 16: ... Memo ...
Page 20: ... Memo ...
Page 22: ... Memo ...
Page 46: ... Memo ...
Page 60: ... Memo ...
Page 62: ... Memo ...
Page 212: ... Memo ...
Page 222: ... Memo ...
Page 224: ... Memo ...
Page 232: ... Memo ...
Page 238: ...Chapter 7 Specifications 7 6 L700 750 LFF 6 Cable hole φ41 ...
Page 239: ...Chapter 7 Specifications 7 7 L700 900 to 1100HFF L700 1320 to 1600HFF ...
Page 240: ... Memo ...
Page 242: ... Memo ...
Page 258: ... Memo ...