SSB2
RAID Manager
command
Cause of error
97C7
paircreate
You cannot create the FS pair because the capacity of cache
management devices is insufficient.
97C8
paircreate
You cannot create the FS pair because the capacity of the volume you
specified as the P-VOL or the S-VOL of the FS pair is more than the
supported size.
97CB
All commands
The command ended abnormally because you specified a pool that is
neither an FS pool nor a THP pool.
97CD
paircreate/map
snapshot
The command ended abnormally because you specified a
deduplication system data volume as the P-VOL of a Fast Snap pair.
97CE
paircreate/map
snapshot
The command ended abnormally because you specified a
deduplication system data volume as the S-VOL of a Fast Snap pair.
97CF
paircreate
You cannot create the FS pair because an FS group is already using
the CG number you specified.
97D4
All commands
The command ended abnormally because you are in the process of
turning off the power.
97D5
All commands
You cannot run the command because even though the specified
serial number matches the virtual storage machine, the physical
storage system's serial number that corresponds with the virtual
storage machine's serial number does not match when the virtual
storage machine's serial number is specified for P-VOL and S-VOL.
97D6
All commands
You cannot run the command because the model, serial number, or
virtual LDEV ID of the volume specified as P-VOL is being changed.
97D7
All commands
You cannot run the command because the model, serial number, or
virtual LDEV ID of the volume specified as S-VOL is being changed.
97D8
All commands
The pair operation was rejected because one of the following
conditions holds for the volume that is specified as the FS P-VOL:
• The volume is used as a High Availability pair volume and does not
accept pair operations.
• The volume is specified reservation attribute of a High Availability.
97D9
All commands
The pair operation was rejected because one of the following
conditions holds for the volume that is specified as the FS S-VOL:
• The volume is used as a High Availability pair volume.
• The volume is specified reservation attribute of a High Availability.
Table Continued
RAID Manager command reference for Fast Snap
205
Summary of Contents for HPE XP7
Page 7: ...Documentation feedback 311 Contents 7...
Page 24: ...24 Overview of Fast Snap...
Page 109: ...2 In the Replication window click Edit Options Local Replication Configuring Fast Snap 109...
Page 186: ...186 Troubleshooting Fast Snap...
Page 187: ...Troubleshooting Fast Snap 187...
Page 214: ...The following table lists the items on this tab 214 Fast Snap GUI windows and wizards...