Problem
Causes and solutions
RWC times out frequently. Causes:
• RWC cannot respond to the SVP because the load is too heavy.
• The time-out period is not an adequate length.
Solutions:
• Wait until the process has completed and then retry the task.
• Verify the values for the RWC
RMI time-out period
.
For more information about how to set RMI time-out period, see the
HPE XP7
Remote Web Console User Guide
.
The pair information in the
Local Replication
window
is not updated. The date
and time in
Last Updated
is not updated.
Cause: FS processing may be in progress.
Solution: The update will complete sometime after the FS processing finishes.
After a host completes a
write operation, the used
pool capacity shown in the
Summary
section of the
Pools
window and in the
list in the
Primary
Volumes
tab of the
selected pool do not
match.
Cause: The copy processing is running.
Solution: Wait until the copy processing is completed. The used pool capacity
shown in the
Summary
section of the
Pools
window and in the list in the
Primary
Volumes
tab of the selected pool match.
For more information about viewing the used pool capacity in this section and on
this tab, see
on page 151.
Table Continued
Troubleshooting Fast Snap
183
Summary of Contents for HPE XP7
Page 7: ...Documentation feedback 311 Contents 7...
Page 24: ...24 Overview of Fast Snap...
Page 109: ...2 In the Replication window click Edit Options Local Replication Configuring Fast Snap 109...
Page 186: ...186 Troubleshooting Fast Snap...
Page 187: ...Troubleshooting Fast Snap 187...
Page 214: ...The following table lists the items on this tab 214 Fast Snap GUI windows and wizards...