SSB2
RAID Manager
command
Cause of error
9722
paircreate, pairsplit,
pairresync,
pairresync -restore
The command ended abnormally because you specified either of the
following for the FS P-VOL.
• External volume for which the Data Direct Mapping attribute is
enabled.
• Normal volume for which capacity expansion is enabled
These volumes can only be used as pool volumes.
9723
All commands
The command ended abnormally because shared memory (64KLDEV
Extension) is not added.
9724
All commands
The command ended abnormally because shared memory (64KLDEV
Extension or greater) is not added.
9725
All commands
The command ended abnormally because the LDEV number of the
volume you specified as the FS P-VOL is beyond the specified range.
9726
All commands
The command ended abnormally because you specified an
unmounted volume as the FS P-VOL.
9727
paircreate, pairsplit,
pairresync,
pairresync -restore
The command ended abnormally because you specified a blocked
volume as the FS P-VOL.
9728
paircreate, pairsplit,
pairresync,
pairresync -restore
The command ended abnormally because you specified a volume that
is in the process of being shredded or formatted as the FS P-VOL.
9729
paircreate, pairsplit,
pairresync,
pairresync -restore
The command ended abnormally because you specified a volume as
the FS P-VOL, and that volume has an emulation type other than
OPEN-V.
972A
paircreate
You cannot create the FS pair because the volume you specified as
the FS P-VOL has the command device setting.
972C
paircreate
You cannot create the FS pair because the capacity of the volume you
specified as the FS P-VOL exceeds the supported size.
972E
paircreate
You cannot create the FS pair because the capacity of the volume you
specified as the FS S-VOL exceeds the supported size.
972F
paircreate
You cannot create the FS pair because you specified a V-VOL as the
FS P-VOL.
9730
paircreate
You cannot create the FS pair because you specified a pool-VOL as
the FS P-VOL.
Table Continued
198
RAID Manager command reference for Fast Snap
Summary of Contents for HPE XP7
Page 7: ...Documentation feedback 311 Contents 7...
Page 24: ...24 Overview of Fast Snap...
Page 109: ...2 In the Replication window click Edit Options Local Replication Configuring Fast Snap 109...
Page 186: ...186 Troubleshooting Fast Snap...
Page 187: ...Troubleshooting Fast Snap 187...
Page 214: ...The following table lists the items on this tab 214 Fast Snap GUI windows and wizards...