127
4-2-2 Adjustment of TC board
Viewing from side of circuit board, set slit so that it comes to center of sensor, fix it.
4-2-3 Adjustment of stop position of needle bar change unit
1. Remove potentiometer ass’y.
Mac. No.
〜
1056034A
Mac. No.
1057001A
〜
2. Set position where sensor on sensor board and slit don't cross to area where moving head doesn't move
when turning groove cam.
3. After installation, please fix potentiometer referring to [3-4-2 Setting to detect needle position].
Imagine figure of position sensor and cam