Chapter 1 PLC Window Display
67
Ⅱ
Operation
used for trigger stopping)
2. Mode; It determines that what kind trigger mode is used to stop tracing.
Rising edge: The tracing is automatically stopped by the rising edge of the trigger signal.
Falling edge: The tracing is automatically stopped by the falling edge of the trigger signal.
Any change: The tracing is automatically stopped by the rising or falling edge of the trigger
signal.
(6) Sampling condition: This parameter is enabled when the sampling mode is set to “signal
change”, which is determined the sampling condition.
- - Signal trigger: The specified mode changes when the signal specified by the trigger
address which is set by the sampling condition, collect the signal.
- - Any change: Any change occurs when the signal specified by the trigger address which is
set by the sampling condition.
Trigger setting: When the sampling mode is set to “signal change”, and then the sampling
condition is set to “signal trigger”, this parameter is enabled.
1. Address: The input signal address, instead of using the R address, is treated as the sampling
of the trigger signal.
2. Mode: The trigger mode inputs the specified trigger signal.
Rising edge: The rising edge sampling of the trigger signal specifies the signal state.
Falling edge: The falling edge sampling of the trigger signal specifies the signal state.
Any change: Specify the signal state by the rising or falling edge sampling of the trigger signal.
Switch on: Sample the specified signal state when the trigger signal is switched on.
Switch off: Sample the specified signal state when the trigger signal is switched off.
Enter the PLCTRACE “trace” interface by pressing the [trace] soft key. Refer to the 1-2-5-2:
Fig.1-2-5-2