GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
154
Inst
allation
and
Connection
Ⅳ
2
HA-
4
HB-
1
3
14
+5V
HA+
HB+
Metal shell
A
B
Handhold unit
8
HZ
23
22
9
H*100
H*10
H*1
12
0V
24
ESP1
11
0V
ESP1
0V
Z
EN
ESP2
X100
X10
X1
10
0V
7
6
5
HU
HY
HX
U
Y
X
Metal shell
17
+24V
13
OV
LED+
LED-
XS38
DB26
(
Eyelet welding
)
Terminal strip
VCC
FG
Fig. 2-4-2-3
2.4.3 Handhold Unit’s Interface Circuit
a
)
The handhold unit receives only 0V level input instead of 24V input.
b
)
The axis selection and override signal circuit are shown in Fig 3-2-2-1: