![GSK 980TC3 Series Manual Download Page 221](http://html.mh-extra.com/html/gsk/980tc3-series/980tc3-series_manual_2275232221.webp)
Appendix 4 Common Debugging Method
209
Appendix
Appendix 4 Common Debugging Method
1.1 Zero Return Method and Common Parameter Setting
Press
,
and then press the soft key
【
CNC SETTING
】
in
page to enter the
CNC setting page:
a) When the parameter switch input is 1, the parameter switch is ON, and when it is 0, the switch is
OFF.
b) Move the cursor to the authority setting area to select the machine factory’s password, input the
initial password. The password can be modified.
Note: The password is not always digits, and it also contains “Input key”.
c
)
After modification, inputting a mistaken password again or the previous password after power off
is invalid, the password after modified is input again, unless the system is initialized to return to
the initial password “111111”
,
otherwise, the password is defaulted to the last modified
password.
d
)
After the above item a, b are correctly performed, values in the 6 display pages
【
BITPAR
】
,
【
DATAPAR
】
,
【
MARCOVAR
】
,
【
OFFSET
】
,
【
BUS
】
and
【
LADDERPAR
】
.
e
)
Absolute zero return: setting zero in the bus allocation is shown in the following figure. Firstly move
the cursor to the axis number 1 “Setting” , then press the input key twice, and X zero return light is
ON on the system panel; move the cursor to the axis number 3 “Setting” , then press the input key
twice, and Z zero return light is ON on the system panel; input the positive/negative border
according to the machine’s actual position.
Note: The positive/negative border is set according to the actual machine coordinates by manually moving
the machine’s each axis. Setting a safety border is to prevent the programming personnel from big
data, from impacting the machine, and other axes are set based on the above operations.
Fig. 1-1-1