Chapter 1 PLC Window Display
65
Ⅱ
Operation
Fig. 1-2-4-1
Contents and operations on PLCDGN interface:
RUN
:
operation state of ladder.
ADDR
:
address of diagnosis number.
N.0~N.7
:
bit number state of diagnosis address.
1
:
the signal is connected
;
0
:
the signal is not connected.
Input: display the input data.
MDI mode: current operation mode.
Press the Page Up/Page Down, four Direction keys to search the corresponding diagnosis
number.
Generally, only the searching can be operated in the interface, the I/O interface of PLC enters the
signal debug mode only when the user gets the authority to set K0.1 to 1. At the moment, the
user can modify the X, Y signal.
1.2.5 PLCTRA Interface
PLCTRA interface is consist of two interfaces “Setting” and “TRACE” . Press
【
PLCTRA
】
to
enter PLCTRA “SETTING” interface.
PLCTRA “SETTING”
interface is shown in Fig.1-2-5-1: