GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
110
Ⅲ
Function
AFL
(
G005
#
6
)
[
Classification
]
Input signal
[
Function
]
The signal selects the auxiliary function lock, i.e., the signal disables the
execution of the specified M, S, T function.
[
Operation
]
When the signal becomes 1, the control unit functions are as follows:
1. The control unit does not execute M, S, and T functions. That is, the control unit
stops the output of code signals and strobe signals.
2. If this signal becomes “1” after code signal output, the output operation is
executed during the ordinary manner until its completion( that is, until the FIN
signal is received, and the strobe signal becomes to “0”.)
3. Among the miscellaneous function, M00,M01
,
M02 and M30 are executed even
when this signal is “1”. All code signals, strobe signals, decode signals are output
during the ordinary manner.
4. Even when this signal is “1”, M98 and M99 are executed during the control unit
without outputting their execution results are executed during the ordinary
manner.
Warning
Even when this signal is “1”, THE spindle analog voltage output is executed.
Auxiliary function lock check signal
MAFL
(
F004
#
4
)
[
Classification
]
Output signal
[
Function
]
The signal reports the state of auxiliary function lock signal AFL.
[
Output conditions
]
When the signal is 1, the auxiliary function lock signal AFL is1.
When the signal is 0, the auxiliary function lock signal AFL is 0.
Signal address
AFL
G005
#
7
#6
#
5
#
4
#
3
#
2
#
1
#
0
MAFL
F004