![GSK 980TC3 Series Manual Download Page 179](http://html.mh-extra.com/html/gsk/980tc3-series/980tc3-series_manual_2275232179.webp)
Chapter 4 Machine Debugging
167
Inst
allation
and
Ⅳ
connection
Chapter 4 Machine Debugging
The chapter introduces the trial operation methods and steps after GSK980TC3 system
is turned
on firstly, and the corresponding machine operation can be performed after the following steps are
done.
4.1 Debug Preparation
Debugging GSK980TC3 can be operated based on the following steps:
z
Connection of the system: The correct connection is the base of the system debugging;
z
PLC debugging: Make the system safety function (such as the emergency stop and hardware
limit, etc) and the operation function effective;
z
Setting the drive unit parameters: Set the parameters of the motor type and the control mode,
etc.
z
Setting the system parameters: Set the control and the speed parameters, etc.
z
Data backup: After the system debugging, the data, such as the parameter, compensation
data and PLC program, should be backup.
Pay attention to the following matters before debugging and running GSK980TC3:
z
Check the fly-wheel diode polar of the relay and the solenoid valve to guarantee all the cables
connected correctly.
z
Check the connection phase sequence of strong current cables of the motor.
z
Check the corresponding relations between the position control cable, the coded wheel
feedback cable and the motor strong current cable of AC servo feed unit.
z
Confirm the type of the analog voltage code received by the spindle.
z
Confirm all the earth wires are connected properly.
z
Confirm the usefulness of the emergency stop button and the emergency stop return circuit.
Make sure that the power supply of the drive device and that of the spindle drive device are
OFF after pressing the emergency stop button or disconnecting the emergency return circuit.
z
Confirm the voltage of each circuit power supply is correct and the polar is connected right.
z
Confirm the power supply specification in each circuit is correct.
z
Confirm each transformer specification and in-out direction in the circuit is correct.
z
Confirm the power supply in-out circuit direction of each breaker is correct.
4.2 System Power-on
z
Press the emergency stop button and make sure all the air switches are OFF.
z
Switch on the air switch of the main power supply in the cabinet.
z
Connect the air switch controlling DC24V or the fuse and check whether DC24V power
supply is normal or not.
z
Check whether the power supply of the other parts is normal or not.
z
Electrify GSK980TC3 CNC device.
Summary of Contents for 980TC3 Series
Page 13: ...1 Programming Ⅰ Programming Ⅰ ...
Page 71: ...59 Operation Ⅱ Ⅱ Operation ...
Page 97: ...85 III Ⅲ Function III Function ...
Page 149: ...137 Installation and Connection Ⅳ Ⅳ Installation and Connection ...
Page 209: ...197 附 录 Appendix ...