GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
200
Appendix
D000
4
The tool post’ total tool
quantity
Set it according to the adaptive tool post
D001
0000
The servo alarm coded
value
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
D002
0001
The servo ready OK
coded value
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
D003
0002
Coded value in the servo
zero return
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
D004
0005
The servo zero return
completion coded value
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
D005
0004
Coded value in servo
rotating
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
D006
0004
Tool number display
reduction
According to DO01-05 corresponding to the driver’s
manual: status’s binary system into coded-decimal
code
⑤
Relevant alarms
No. Content
Treatment
A5.0/1240
The tool post ready is not
OK
Check whether PLC-TMR040 parameter setting is too
small
Check whether the servo drive is normal, DO1-DO5 circuit
is broken, and the input signal is normal
Check whether Y2.7, S8(X2.6) signal, the circuit of turret’s
oil pressure are normal
A5.1/1241
After the tool post servo
is ready OK, the tool post
zero return is executed
after reset
Execute the turret zero return
A5.2/1242
The tool post locking
check is abnormal
Check whether PLC-TMR038 parameter setting is too
small
Check whether Y3.4, S8(X2.6) signal, the circuit of turret’s
oil pressure are normal
A5.3/1243
The tool post releasing
check is abnormal
Check whether PLC-TMR039 parameter setting is too
small
Check whether Y3.5, S8(X2.7) signal, the circuit of turret’s
oil pressure are normal
A5.4/1244
The tool post zero return
completion signal
checks abnormality
Check whether PLC-TMR041 parameter setting is too
small
Check whether Y3.4, S8(X2.6) signal, the circuit of turret’s
oil pressure are normal
Check whether PLD-D4 is correct
A5.5/1245
The tool post signal is
abnormal. Execute zero
return again
Execute the zero return again
A5.6/1246
The servo tool post
searching a tool is
overtime
Check whether PLC-TMR042 parameter setting is too
small
Check whether the servo drive is normal, DO1-DO5 circuit
is broken, and the input signal is normal
A6.0/1248
The tool post’s servo
driver alarms. Restart
Check whether the servo driver alarms
Restart the machine and check whether the alarm still
exists