Chapter 6 Feedrate Control
103
Ⅲ
Operation
Chapter 6
Feedrate Control
6.1 Rapid Traverse Rate
General
The 4 gears ( F0
,
25
%,
50
%
, 100%) can be used for rapid traverse rate.
Feedrate: Actual moving speed is obtained by multiplying the override value by the value
set by the data parameter P088~092 either in the auto mode or
manual operation mode (including manual reference point return
and program zero return).
F0
:
it is set by the data parameter P093.
Signal rapid traverse override coded signal
(
G14#0~G14#2
)
[
Classification
]
Input signal
[
Function
]
It is the rapid traverse override signal
[
Operation
]
The coded signal is corresponded to the following override
Rapid traverse override coded signal
Override value
RV4
RV2
RV1
ROV1=0
ROV2=1
0
0
0
0%
0%
0
0
1
25%
20%
0
1
0
50%
40%
0
1
1
100%
60%
1
0
0
——
80%
1
0
1
——
100%
6.2 Feedrate Override
General
A programmed feedrate can be reduced or increased by a percentage selected by the
override dial. This feature is used to check a program. For example, when a feedrate of
100 mm/minute is specified during the program, setting the override to 50% to move the
tool at 50 mm/min.
Signal
Feedrate override coded check signal
(
G012#0~G012#4
)
[
Classification
]
Input signal
[
Function
]
Cutting feedrate override signal divided into 5 binary coded signals which
are corresponded to the override:
The override can be selected with 10% increment within 0~200%.
[
Operation
]
Actual feedrate is obtained by multiplying the specified speed by the
override value selected by this signal.
[
Operation
]
The coded signal is corresponded to the following override
Cutting feedrate override coded signal
FV16 FV8 FV4 FV2 FV1
Override value
0 0 0 0 0 0%
Summary of Contents for 980TC3 Series
Page 13: ...1 Programming Ⅰ Programming Ⅰ ...
Page 71: ...59 Operation Ⅱ Ⅱ Operation ...
Page 97: ...85 III Ⅲ Function III Function ...
Page 149: ...137 Installation and Connection Ⅳ Ⅳ Installation and Connection ...
Page 209: ...197 附 录 Appendix ...