Chapter 4 Machine Debugging
187
Inst
allation
and
Ⅳ
connection
=0: Before connecting the power supply and the reference point return, the rapid in JOG
mode is invalid.
LRP
=1: Positioning (G00) interpolation type is linear.
=0: Positioning (G00) interpolation type is non-linear.
RFO
=1: Rapid feeding, when the feed override is Fo, the feeding stops.
=0: Rapid feeding, when the feed override is Fo, the feeding doesn’t stop.
FDR
=1: During cutting feed, dry run is valid.
=0: During cutting feed, dry run is invalid.
RDR
=1: During rapid positioning, dry run is valid.
=0: During rapid positioning, dry run is invalid.
0086
Dry run speed
5000
Setting range: 0
~
9999 (mm/min)
0087
The cutting feedrate when power-on
300
Setting range: 0
~
9999 (mm/min)
0088
G0 rapid positioning speed of the 1
st
axis
5000
Setting range: 0
~
30000 (mm/min)
0089
G0 rapid positioning speed of the 2
nd
axis
5000
Setting range: 0
~
30000(mm/min)
0090
G0 rapid positioning speed of the 3
rd
axis
5000
Setting range: 0
~
30000 (mm/min)
0091
G0 rapid positioning speed of the 4
th
axis
5000
Setting range: 0
~
30000 (mm/min)
0092
G0 rapid positioning speed of the 5
th
axis
5000
Setting range: 0
~
30000(mm/min)
0093
Fo speed of rapid override of each axis (for all axes)
30
Setting range: 0
~
1000 (mm/min)
0094
Maximum feedrate during rapid positioning (for all
axes)
8000
Setting range: 300
~
30000 (mm/min)
0095
The lowest feedrate during rapid positioning (for all
axes)
0
Setting range: 0
~
300 (mm/min)
0096
The maximum control speed during cutting feed (for
all axes)
6000
Setting range: 300
~
30000 (mm/min)