GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
186
Inst
allation
and
Connection
Ⅳ
Fig.4-11-1
z
The external circuit
The connection between *SP and ST signals is referred to the following Fig. 4-11-2.
+24V
*SP
ST
System
side
XS40
socket
Fig. 4-11-2
z
Modifying the following parameter
4.12 Cooling, Lubricating Control
z
Relative M codes
M08
:
cooling ON
M09
:
cooling OFF
z
Signal
diagnosis
System diagnosis
(
output state at side of the system
)
State
address
Y03
Y0.1
Pin
GL200(Y0.3)
GL200(Y0.1)
Y0.1=cooling
;
Y0.3=lubricating
z
The internal circuit is referred to the following Fig. 4-12-1:
+24V
M08
ULN2803
System side
M08 internal circuit
Fig. 4-12-1
4.13 Setting the Relative Feedrate
System parameter number
0 1 2
RDR FDR
RFO
LRP RPD
RPD
=1: Before connecting the power supply and the reference point return, the rapid in JOG
mode is valid.
Address
Definition
State 0
State 1
Setting
value
K005.1
Whether the machine is with
the external cycle start
No Yes
1