GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
100
Ⅲ
Function
[
Function
]
The signal reports PLC of the state of all-axis machine tool lock signal.
[
Output condition
]
When the signal is set to 1, all-axis machine tool lock signal is set to 1.
When the signal is set to 0, all-axis machine tool lock signal is set to 0.
Signal address
5.3.2 Dry Run
General
Dry run is valid only for automatic, MDI operation. The machine moves at a constant
feedrate regardless of the feedrate specified in the program. The feedrate is set by P86.
This function is used to check the movement of the machine without a workpiece.
Signal Dry run signal
DRN
(
G046
#
7
)
[
Classification
]
Input signal
[
Function
]
Enables dry run.
[
Operation
]
When the signal is set to 1, the machine tool moves at the feedrate
specified for dry run.
When the signal is 0, the machine tool normally moves.
Note
:
When the dry run signal is changed from 0 to 1 or 1 to 0 during the movement of the
machine, the feedrate of the machine is first decelerated to 0 before being accelerated
to the specified feedrate.
Signal address
5.3.3 Single Block
General
When the single block signal (SBK) is set to 1 in Auto, MDI mode, the CNC enters the
automatic operation stop state after executing the current block. In subsequent automatic
operation, the CNC enters the automatic operation stop state after executing each block
in the program. When the single block signal (SBK) is set to 0, normal automatic
operation is stored.
Signal Single block signal
SBK
(
G046
#
1
)
[
Classification
]
Input signal
[
Function
]
Enables single block operation.
[
Operation
]
Execute the single block when the signal is set to1.
Execute the normal operation when the signal is set to 0.
Single block check signal
MSBK
(
F004
#
3
)
MMLK
F004
#
7
#
6
#
5
#
4
#
3
#
2
#
1
#
0
DRN
G046
#
7
#
6
#
5
#
4
#
3
#
2
#
1
#
0