Chapter 2 Preparation for Operation
91
Ⅲ
Function
2.4 Operation Mode Selection
Signal
Mode selection signal
Set the following mode to select modes by signals
Mode selection signal
MD1,MD2,MD4
(
G043#0
~
#2
)
Manual reference point return’s selection signal
ZRN
(
G043#7
)
Incremental feed selection signal
INC
(
G043#3
)
MPG trial cut selection signal
TEACH
(
G043#4
)
Program zero return selection signal
PRGZ
(
G043#6
)
Run mode check signal
Incremental feed selection confirmation signal
MINC
(
F003#0
)
MPG feed selection confirmation signal
MH
(
F003#1
)
Manual continuous feed selection confirmation signal
MJ
(
F003#2
)
Manual data input selection confirmation signal
MMDI
(
F003#3
)
Storage run selection confirmation signal
MMEM
(
F003#5
)
Program edit selection confirmation signal
MEDT
(
F003#6
)
MPG trial cut selection confirmation signal
RHPG
(
F006#3
)
Manual reference point return selection confirmation signal
MREF
(
F004#5
)
Table 2-4-1 relationship between mode selection signal and confirmation signal
Input signal
MD1 MD2 MD4
INC
TEACH PRGZ
ZRN
Mode
G43.0 G43.1 G43.2 G43.3
G43.4
G43.6 G43.7
Output
signal
Manual data
input(MDI)
0 0 0 - - - -
MMDI
Storage run
(Auto mode)
1 0 0 - 0 - -
MMEM
Automatic
run
MPG trial cut
1
0
0
-
1
-
-
RHPG
Storage edit
(EDIT)
1 1 0 - - - -
MEDT
MPG 0
0
1
0
-
-
-
MH
Incremental feed
(Step)
0 0 1 1 - - -
MINC
Manual JOG
feed
1 0 1 - - - 0 MJ
Manual reference
point return
1 0 1 - - 0 1
MREF
Manual
run
Program zero
return
1 0 1 - - 1 1