GSK980TC3 Series Bus Turning CNC system PLC, Installation and Connection User Manual
104
Ⅲ
Function
0 0 0 0 1 10%
…… …… …… …… ……
……
……. …… …… …… ……
……
1 0 0 1 1 190%
1 0 1 0 0 200%
6.3 Override Cancel
General
The override cancel signal fixes the feedrate override to 100%.
Signal
Override cancel signal
OVC
(
G006
#
4
)
[
Classification
]
Input signal
[
Function
]
The feedrate override is fixed to 100%.
[
Operation
]
When the signal is 1, CNC operates as follows:
z
The feedrate override is fixed to 100% irrespective of the feedrate
override signal.
z
Rapid traverse override and spindle speed override are not affected.
Signal address
OVC
G006
#
7
#
6
#
5
#
4
#
3
#
2
#
1
#
0