3
2
4
1
Network
color
Signal
name
PHY1_RX-
PHY1_TX-
No.
4
1
2
3
Network
color
Signal
name
Wire
GT17VS-4DS-HU(KEYC blue)
XS12
GT17VS-8DS-HU(Line ball)
GE series CN1
Orange
Green and
white
Green
Orange
and white
Green and
white
Green
Orange
Orange
and white
PHY1_RX-
PHY1_TX-
Note:1. Industrial Ethernet type
:
IE-5CC4*2*AWG26/7-PVC
(
Weidmuller
)
PG
Shielding net
PG
Shielding net
GT17-4DS-HU
(
KEYC blue
)
connected with T17-8DS-HU
Fig. 2-2-3-3 Connection between CNC terminal bus interface 2 and driver
No.
4
5
6
7
8
1
2
3
Network
color
Signal
name
RX-
(BI_DA-)
RX+
(BI_DA+)
TX-
(BI_DB-)
TX+
(BI_DB+)
reserved
(BI_DC-)
No.
4
5
6
7
8
1
2
3
Network
color
Signal
name
Wire
GT17VS-8DS-HU(Line ball)
GE series CN2
GT17VS-8DS-HU(Line ball)
GE series CN1
reserved
(BI_DC+)
reserved
(BI_DD-)
reserved
(BI_DD+)
Green
Orange
and white
Orange
Green and
white
Blue and
white
Blue
Brown and
white
Brown
Orange
and white
Orange
Green
Green and
white
Blue and
white
Blue
Brown and
white
Brown
RX-
(BI_DA-)
RX+
(BI_DA+)
TX-
(BI_DB-)
TX+
(BI_DB+)
reserved
(BI_DC-)
reserved
(BI_DC+)
reserved
(BI_DD-)
reserved
(BI_DD+)
GSK_LINK industrial Ethernet wire(GT17 interface)
Fig. 2-2-3-4 connection among drivers