Appendix 3 Ladder Configuration File Format
207
Appendix
Appendix 3 Ladder Configuration File Format
The signal in configuration file LadChixx.txt of ladder (“xx” corresponds to the running ladder file
number set by the system) stores the following information by fixed sequence.
1. F Signals and Meanings of M Code M00---M99
Format: MXX + space + Fyyyy + space + Chinese notes + EOB symbol(enter)
Example: “M00 F0317 program pause”
Thereinto: ”xx” from up to down is 00, 01, 02.. till to 99, it totals 100. and its sequence cannot be
altered.
Generally, “Space” is one space, which cannot be adulterated by any other
characters.
“
yyyy
” means the M code corresponds to F signal value, i.e.
F0317
represents
F31.7
”. it may
set from 0260 to 0337 (i.e. F signal from 26.0 to 33.7). if it is set to “
-001
” , it means no
registration is allowed and it cannot be identified by system.
”Chinese remark” contains up to 32 characters, it may has 16 Chinese characters or
equivalent Chinese char characters. The following is same as this.
”EOB symbol” means the end of the line and the characters following will not be identified. The
following is same as this.
2. “%” that Occupies a Line Exclusively Means the End of M Code Information
Storage.
3. The Codes and Meanings of X Signal X0.0-X6.7
Format: Xxxxx + space + Chinese EOB symbol (enter)
Example: “X0000 the 1st axis limit signal (positive direction with double-switch)”
Thereinto: “xxxx” means the value of X signal, i.e. “0000 for 0.0”
,
“0067 for 6.7”. and it is from
0000 to 0067 from up to down(i.e. X signal from 0.0 to 6.7), its sequence can’t be
altered.
“Space” generally includes 5 spaces, which cannot be adulterated by any other
characters. The following is same as this.
4. The Codes and Meaning of Y Signal Y0.0---Y5.7
Format: Yxxxx + space + Chinese notes + EOB symbol(enter)
Example: “Y0000 lubricating output ”
Thereinto: “xxxx” means the value of Y signal, i.e. “0000 for 0.0”
,
“0057 for 5.7”. and it is
from 0000 to 0057 from up to down(i.e. Y signal from 0.0 to 5.7), its sequence can’t be altered
5. The Codes and Meanings of K Signal Y6.0---Y63.7
Format: Kxxxx + space + Chinese EOB symbol(enter)
Example: “K0060 Whether one limit switch is used or not”
Thereinto : “xxxx” means the value of K signal, i.e. “0060 for 6.0”
,
“0637 for 63.7”. and it is from
0060 to 0637 from up to down(i.e. K signal from 6.0 to 63.7), its sequence can’t be
altered.
“Space” generally includes 5 spaces, which cannot be adulterated by any other
characters.