L
:
rising edge number, range 0~255. Another DIFU instruction or DIFD instructin in
the ladder uses the same number, the system will alarm.
Operation
:
Execution period
5.20 COMP
(
binary comparison
)
Function:
Compares binary values. Specifies enough byte to store input data and comparison data in the
memory.
Format:
Control conditions:
ACT
=
0: The COMP instruction is not executed. W does not alter.
ACT
=
1: The COMP instruction is executed.
Parameter:
Length
:
specification format( constant or address) and data length(1 or 2 bytes) for the
input data.
S1, S2: content of comparison source 1 and comparison source 2. It can be
O O
Specification of data length
1
:
1 byte length data
2
:
2 byte length data
Specification of format
0
:
Constant
1
:
Address
ACT
COMP
Length
Designation
format
S2
comparison
data
S1 input data
address
1 2 3 4
(