GSK218M CNC System Connection and PLC Manual
21
2.5.4 Difference o fstate of signals between 1
st
level and 2
nd
level
The state of the same input signal may be different in the 1
st
level and 2
nd
level sequences. That is,
at 1
st
level, processing is performed using input signal memory and at 2
nd
level, processing is
performed using the 2
nd
level synchrounous input signal memory. Therefore, it is possible for a 2
nd
level sequence execution at the worst, compared with a 1
st
level input signal.
This must be kept in mind when writing the sequence program.
B1 and B2 are not 1 simultaneously after the signal A is processed synchronously by the medium
relay.
R
B1
END1
B2
A
B1
A
B2
END1
When A=0, and B1=1, A becomes 1, at this time, the next line of ladder is executed, B2=1. B1
and B2 are also 1.
Summary of Contents for 218M
Page 3: ...GSK 218M CNC System Connection and PLC Manual...
Page 15: ...GSK218M CNC System Connection and PLC Manual 12 Volume one Programming...
Page 70: ...GSK218M CNC System Connection and PLC Manual 67 Volume Two Function...
Page 140: ...GSK218M CNC System Connection and PLC Manual 137 Volume Three Operation...
Page 160: ...GSK218M CNC System Connection and PLC Manual 157 Volume Four Connection...