Figure 15-38. Timing chart of up counting mode, change TIMERx_CAR ongoing
TIMER_CK
CEN
CNT_CLK(PSC_CLK)
CNT_REG
5E
5F
60
61
62
63
00
01
02
03
04
05
06
07
Update event (UPE)
Update interrupt flag (UPIF)
Auto-reload register
65
63
change CAR Vaule
CNT_REG
5E
5F
60
61
62
63
64
65
00
01
02
62
63
00
Update event (UPE)
Update interrupt flag (UPIF)
Auto-reload register
65
63
change CAR Vaule
65
63
Auto-reload shadow
register
...
Hardware set
Hardware set
Software clear
Hardware set
ARSE = 0
ARSE = 1
Down counting mode
In this mode, the counter counts down continuously from the counter reload value, which is
defined in the TIMERx_CAR register, in a count-down direction. Once the counter reaches 0,
the counter restarts to count again from the counter reload value. If the repetition counter is
set, the update event will be generated after (TIME1) times of underflow.
Otherwise, the update event is generated each time when counter underflows. The counting
direction bit DIR in the TIMERx_CTL0 register should be set to 1 for the down-counting mode.
When the update event is set by the UPG bit in the TIMERx_SWEVG register, the counter
value will be initialized to the counter reload value and an update event will be generated.
If the UPDIS bit in TIMERx_CTL0 register is set, the update event is disabled.
When an update event occurs, all the registers (auto reload register, prescaler register) are
updated.
Figure 15-39. Timing chart of down counting mode, PSC=0/1
chart of down counting mode, change TIMERx_CAR
show some examples of the counter
behavior in different clock frequencies when TIMERx_CAR = 0x63.