Figure 15-27. Single pulse mode TIMERx_CHxCV=0x04, TIMERx_CAR=0x60
TIMER_CK(CNT_CLK)
CEN
CNT_REG
00
01
02
03
04
05
…
.
5F
60
00
O2CPRE
CI3
Under SPM, count er stop
Timers interconnection
The timers can be internally connected together for timer chaining or synchronization. This
can be implemented by configuring one timer to operate in the master mode while configuring
another timer to be in the slave mode. The following figures present several examples of
trigger selection for the master and slave modes.
Figure 15-28. TIMER0 Master/Slave mode timer example
selection when it is configured in slave mode.
Figure 15-28. TIMER0 Master/Slave mode timer example
TIMER0
TIMER 4
Pre scaler
Counter
Master
mode
control
Trigger
selection
ITI0
IT1
ITI1
CI0F_ED
CI0FE0
CI1FE1
ETIFP
TRGS
Slave mode
control
Pre scaler
Counter
TRG O
TIMER 1
Pre scaler
Counter
Master
mode
control
TRG O
TIMER 2
Pre scaler
Counter
Master
mode
control
ITI2
IT1
ITI3
TRG O
TIMER 3
Pre scaler
Counter
Master
mode
control
TRG O
Other interconnection examples:
TIMER2 as prescaler for TIMER0