3 - 24
S-100 • S-105 • S-120 • S-125
Part No. 1268494
March 2017
Section 3 • Repair Procedures
9 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
10 Turn the key switch to ground control.
11 Test all machine functions from the ground
controls.
Result: All ground control functions should not
operate.
12 Using a suitable lifting device, lift the test weight
off the platform floor.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls.
Note: There may be a 2 second delay before the
overload indicator lights and alarm turn off.
13 Test all machine functions from the ground
controls.
Result: All ground control functions should
operate normally.
14 Turn the key switch to platform control.
15 Test all machine functions from the platform
controls.
Result: All platform control functions should
operate normally.
PLATFORM COMPONENTS
7 Move the platform up and down by hand, so
it bounces approximately 2.5 to 5 cm / 1 to 2
inches. Allow the platform to settle.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Proceed to step 8.
Result: The overload indicator lights are flashing
at the platform and ground controls, and the
alarm is sounding. Repeat this procedure
beginning with step 5.
Note: There may be a 2 second delay before
the platform overload indicator light and alarm
responds.
8 Add an additional test weight to the platform.
S-105 and S-125- 10 lb / 4.5 kg
S-100 and S-120- 12 lb / 5.4 kg.
Result: The alarm should be sounding.
The platform overload indicator light should be
flashing at the platform controls and “PLATFORM
OVERLOAD” should be displayed on the LCD
screen at the ground controls. Proceed to step 9.
Result: The alarm should be off. The platform
overload indicator light should be off at the
platform controls and there should be no error
message on the LCD display at the ground
controls. Remove the additional 10 lb / 4.5 kg
test weight. Repeat this procedure beginning
with step 6.
Note: There may be a 2 second delay before
the platform overload indicator light and alarm
responds.
Summary of Contents for S-100
Page 246: ...March 2017 Section 6 Schematics 6 22 Safety Circuit Schematic 6 21 ...
Page 259: ...Section 6 Schematics March 2017 6 35 6 36 Electrical Schematic Generator Options ...
Page 262: ...March 2017 Section 6 Schematics 6 38 6 37 Electrical Schematic 12 kW Generator welder option ...
Page 264: ...March 2017 Section 6 Schematics 6 40 Perkins 1104D 44T Engine Electrical Schematic 6 39 ...
Page 265: ...Section 6 Schematics March 2017 6 41 Perkins 854F 34T Engine Electrical Schematic 6 42 ...
Page 268: ...March 2017 Section 6 Schematics 6 44 Perkins 854F 34T Engine Harness 6 45 ...
Page 269: ...Section 6 Schematics March 2017 6 45 Deutz TD2011L04i Engine Electrical Schematic 6 46 ...
Page 271: ...Section 6 Schematics March 2017 6 47 Deutz TD2 9 Engine Electrical Schematic 6 48 ...
Page 274: ...March 2017 Section 6 Schematics 6 50 Deutz TD2 9 Engine Electrical Harness 6 51 ...
Page 276: ...March 2017 Section 6 Schematics 6 52 6 53 Hydraulic Schematic 12 kW Generator welder option ...