Section 4 • Diagnostic Codes
Power up controller with
problem
corrected
Calibrate Joystick
Self-clearing
(transient)
Primary Ext/Ret Joystick
Primary Up/Down Joystick
Steer Joystick
Primary Boom Ext/Ret switches on
TCON
Primary Boom Up/Down switches on
TCON
Primary Boom Angle
Primary Boom Length
Not calibrated
Just calibrated
Value at 5.0 V
Value Too High
Value Too Low
Value at 0 V
Fault Check (both
buttons pressed)
Fault Check
(unknown angle)
Fault Check
(unknown length)
Initiate one second beep of audible
warning device
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Initiate one second beep of audible
warning device
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Calibrate Joystick
Self-clearing
(transient)
Not calibrated
Just calibrated
Value at 5.0 V
Value Too High
Value Too Low
Value at 0 V
Power up controller with
problem
corrected
Limited Speed and Direction frozen at
zero and neutral, Alarm sounds
Stop all boom functions, allow only
boom retract, once fully retracted allow
boom down. Display message on LCD
Power up controller with
problem
corrected
Power up controller with
problem
corrected
Power up controller with
problem
corrected
Power up controller with
problem
corrected
Power up controller with
problem
corrected
Fault Check (both
buttons pressed)
Primary Boom Up/Down disabled, dis-
play message on LCD
Primary Boom Ext/Retract disabled,
display message on LCD
Stop all boom functions, allow only
boom retract. Display message on LCD
Joystick Speed and Direction frozen
at zero and neutral
Initiate one second beep of audible
warning device
Calibrate Joystick
Self-clearing
(transient)
Value at 5.0 V
Value Too High
Value Too Low
Value at 0 V
Not calibrated
Just calibrated
Joystick Speed and Direction frozen
at zero and neutral
Joystick Speed and Direction frozen
at zero and neutral
Error Source
Error Type
Recovery Actions
Effects
DIAGNOSTIC CODES
Summary of Contents for S-100
Page 246: ...March 2017 Section 6 Schematics 6 22 Safety Circuit Schematic 6 21 ...
Page 259: ...Section 6 Schematics March 2017 6 35 6 36 Electrical Schematic Generator Options ...
Page 262: ...March 2017 Section 6 Schematics 6 38 6 37 Electrical Schematic 12 kW Generator welder option ...
Page 264: ...March 2017 Section 6 Schematics 6 40 Perkins 1104D 44T Engine Electrical Schematic 6 39 ...
Page 265: ...Section 6 Schematics March 2017 6 41 Perkins 854F 34T Engine Electrical Schematic 6 42 ...
Page 268: ...March 2017 Section 6 Schematics 6 44 Perkins 854F 34T Engine Harness 6 45 ...
Page 269: ...Section 6 Schematics March 2017 6 45 Deutz TD2011L04i Engine Electrical Schematic 6 46 ...
Page 271: ...Section 6 Schematics March 2017 6 47 Deutz TD2 9 Engine Electrical Schematic 6 48 ...
Page 274: ...March 2017 Section 6 Schematics 6 50 Deutz TD2 9 Engine Electrical Harness 6 51 ...
Page 276: ...March 2017 Section 6 Schematics 6 52 6 53 Hydraulic Schematic 12 kW Generator welder option ...