ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 243
on a digital output of the master drive programmed as
I01.20 - PL next act
.
With a configuration for a multiple motor, such function can be performed only with the
drives connected on common DC buses.
PI regulator
Speed ratio
calculator
To Analog input set
as "Speed ratio" of
Next Drive
PI regulator
Current Limit
Power Loss Stop
Current Limit
Power Ride Thru
DC link voltage
PLS I gain
23.28984 A/V/s
PLS P gain
0.349347 A/V
PLS Vdc ref
736,307 V
Norm Speed
Speed ref
PLS active
PL next active
PL next factor
DC link voltage
PLR I gain
15.6817 A/V/s
PLR P gain
0.235225 A/V
PL function sel
Off
PLS mains st src
NULL
Figure I00-1: Power Loss Control Function