[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 137
C01.22 AI 1 gain
N/A
RWS
1
-16/16
PP
V-F-S-B
Full
5005
Analog Input 1 gain count value displaying.
How to perform the self-tuning procedure of the Analog input 1, if the input is -10V/
+10V (factory).
Tune Analog input 1 offset
C INTERFACE / C01 An Inp 1
Refer to 0 the position of the potentiometer connected to Analog input 1 terminals.
Enter the
C01.18 - AI 1 offs tune
parameter: "Start…" message will be displayed,
than press [Enter] key to run the procedure.
Wait up to "Autotune End" message will be displayed, than press three time
[Escape]
key.
Tune Analog input 1 gain
C INTERFACE / C01 An Inp 1
Refer to maximum the position of the potentiometer connected to Analog input 1
terminals.
Enter the
C01.19 - AI 1 gain tune
parameter: "Start…" message will be displayed,
than press
[Enter]
key to run the procedure.
Wait up to "Autotune End" message will be displayed, than press three time
[Escape]
key.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...