CASE B)
If
T
BR
>
E
BR
/
P
NBR
that is to say, in case of very long braking time, it
must be dimensioned
P
MB
≤
≤
≤
≤
≤
P
NBR
Figure 4.8.2.3: Generic Braking Cycle with Triangular Profile
T
C
n,P
P
PBR
T
BR
t
P
MB
If none of the rules are met, it is necessary to increase the rated power of the
resistor, respecting the limit of the internal braking unit (reported in table 4.8.2.3),
or an external BU if necessary.
In order to protect these resistors from dangerous overload, software overload
control logic is also available (
STARTUP / Drv & Mot config / BUconfig
menu).
The default parameters in this menu match the recommended resistor pairing
as per table 4.8.2.1.
See chapter 7,
STARTUP / Drv & Mot config / BUconfig
menu, to set values
for a non-standard pairing.
Table 4.8.2.2: Braking Thresholds
Mains voltage
Braking threshold
V
BR
[V]
230Vac
400
400Vac
680
460Vac / 480 Vac
780
575 Vac
965
av
y
4200
When the duty cycle exceeds the data entered, the
BU overload
alarm
automatically occurs in order to prevent possible damages to the resistor.
The following table can be used to choose an external resistor, different from
the standard series.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...