[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 181
D07.10 Ramp out enable
N/A
WSZ
1
0/1
DP
V-F-S-B
Easy 8031
[0] Disabled
[1] Enabled
Ramp function enabling
D07.11 Ramp shape
N/A
RWS
1
0/1
DV
V-F-S-B
Easy 8021
[0] Linear
[1] S-Shaped
Ramp selection. Linear or S-shaped ramp
D07.20 Ramp out mon
[rpm] R
0.00
0.00/0.00
PV
V-F-S-B
Easy 8022
Displaying of the Ramp output signal
D07.21 Ramp Acc state
N/A
R
0
0/1
DV
V-F-S-B
Full
8023
Displaying of the Ramp acceleration state signal:
0= Not acceleration
1 = Acceleration
D07.22 Ramp Dec state
N/A
R
0
0/1
DV
V-F-S-B
Full
8024
Displaying of the Ramp deceleration state signal:
0= Not deceleration
1 = Deceleration
D07.23 Ramp out = 0
N/A
R
0
0/1
DV
V-F-S-B
Full
8025
Ramp output signal different from zero:
0 = Ramp enabled
1 = Ramp disabled
D07.24 Ramp cmds mon
N/A
R
0
0/15
DP
V-F-S-B
Full
8026
Command monitor for the ramp block:
Bit 0 -> Ramp output = 0, if ONE the value is 1
Bit 1 -> Ramp input = 0, if ONE the value is 2
Bit 2 -> Ramp freeze, if ONE the value is 4
Bit 3 -> Ramp out enable
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...