The table below displays various operation states by Sequencer status number:
Sequencer status
State
1
Magnetization running
2
Magnetization completed, Stop
3
Start
4
Fast stop, Stop
5
Fast stop, Start
9
No alarm, drive is read
y
to accept all commands
10
Magnetization running and Start command alread
y
present
12
Alarm active
16
Alarm not active, waiting for reset
TAV3i020
To read the sequencer status of the State Machine, go to menu:
⎡
⎤
R:
S:
DISPLAY A
⎣
⎦
⎡
⎤
DISPLAY A00.00
Output freq A
⎣
⎦
up to
⎡
⎤
DISPLAY A13
Adv Dsply A
⎣
⎦
Press
:
⎡
⎤
Adv Dsply A13.00
Magnetiz Curr A
⎣
⎦
up to
⎡
⎤
Adv Dsply A13.07
Sequencer status A
⎣
⎦
⎡
⎤
Sequencer status
12
⎣
⎦