Index
MENU
MENU
MENU
MENU
MENU
[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 150
ARTDrive V2 series - Instruction Manual
ª
ª
ª
ª
ª
Pick List 2
C14.10 AO 4X type
N/A
RWS
0
0/1
DP
V-F-S-B
Full
6039
It allows to select the Analog output 4X type (EXP-D20A6 optional card is required);
below are shown the selections:
[0] 0..20 mA
[1] 4..20 mA
C14.11 AO 4X scale
N/A
RWS
1 -10
1/0
PP
V-F-S-B
Full
6037
Scale or multiplicative factor of Analog output 2X.
C14.12 AO 4X high lim
[cnt]
RWS
16383
0/32767
PP
V-F-S-B
Full
6035
Analog output 4X count value aimed at obt10V. Value must be higher than zero.
C14.13 AO 4X low lim
[cnt]
RWS
-16384
-32768/0
PP
V-F-S-B
Full
6036
Analog output 4X count value aimed at obtaining -10V. Value must be higher than zero.
C14.20 AO 4X inp
[cnt]
R
0
-32768/32767 PP
V-F-S-B
Full
6038
Analog output 4X count value displaying.
C14.21 AO 4X mon
[%]
R
0
-100/100
PP
V-F-S-B
Full
6009
Analog output 4X value 100% is equal to 20mA.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...