Index
MENU
MENU
MENU
MENU
MENU
[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 214
ARTDrive V2 series - Instruction Manual
SPEED REG / Speed 0 config
N
OTE
!
Menu accessible with Access Level = FULL
The Function of the Speed 0 block is active only in a Sensorless and Field oriented mode.
The Function generates the Speed 0 signal, Spd is zero, and the Reference 0 signal, Ref
is zero. It is possible to set: with
F03.13 - Spd 0 speed thr
and
F03.14 - Spd 0 spd delay
the Speed 0 threshold and delay; with
F03.15 - Spd 0 ref thr
and
F03.16 - Spd 0 ref
delay
the threshold and the delay of the reference 0.
Furthermore withSpd 0 enable it is possible to enable the gain adaptive function with a
Speed 0 value and with
F03.11 - Spd 0 P gain %
and
F03.12 - Spd 0 I gain %
to adapt
the Proportional and Integral gain to a Speed 0 value.
The gains become active when both conditions Spd is zero and Ref is zero are true. They
are not active when Ref is zero is false.
The Speed 0 signal, “Speed = zero”, becomes active when the motor speed is lower
than the “Spd 0 speed thr” threshold.
The signal
F03.19 - Spd 0 dly
is delayed by
F03.14 - Spd 0 spd delay
.
The Reference 0 signal, Ref = zero, becomes active when the speed reference
connected to
F03.00 - Spd 0 ref src
is lower than the
F03.15 - Spd 0 ref thr
threshold.
The signal
F03.20 - Ref 0 dly
is delayed by
F03.16 - Spd 0 ref delay
.
Spd is zero
Ref is zero
Spd is 0 dl
y
Ref is 0 dl
y
InUse SpdP Gain%
InUse SpdI Gain%
Spd 0 ref src
>>Spd 0 P gain<<
>>Spd 0 I gain<<
Spd 0 speed thr
Spd 0 spd dela
y
Spd 0 ref thr
Spd 0 ref dela
y
Norm
Gain
Sal
Gain
SPEED
Spd=0
&
Ref=0
Ref=0
Sbk P gain out
Sbk I gain out
FIgure F03: Speed 0 Config block
F03 SPEED REG / Spd 0 cfg
F03.00 Spd 0 ref src
N/A
RWS
Ipa3210
PList20
PIN
V-F-S-B
Full
3732
Ipa 3210 - Speed ref = Default
It select the origin of the signal of speed zero determine ref= 0. It can be selected among
Ramp, Speed, Null, Int spd 0 ref.
ª
ª
ª
ª
ª
Pick List 20
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...