ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 217
SPEED REG / Adaptive Speed
N
OTE
!
Menu accessible with Access Level = FULL
The Adaptive Speed Gain function is active only in a Sensorless and Field Oriented
mode. It differents gains of the speed regulator according to the variations in the speed
value or another user defined signal (ex. load variations, diameter, PID output, etc ).
The block adapts the gains of the speed regulator according to the signal connected to
the
F04.00 - Adaptive ref src
source (standard connected to
F04.24 - Adapt DigRef
,
block internal value in count) and to the Profile of the set gains.
The Profile of the set gain is stated by:
-
three levels of speed Proportional and Integral gain,
SpdPx gain %
and
Spd Ix
gain %
-
two thresholds (thr),
F04.20 - Adaptive speed 1
and
F04.21 - Adaptive speed 2
,
which define the point of the transitions between the three gain levels (see the
figure)
-
two transition bands,
F04.22 - Adaptive joint 1
and
F04.23 - Adaptive joint 2
, that
define the slope, by straight lines, connecting the gain levels.
Refer to the Speed Gain Profile diagram. It is possible to set the value of the internal
reference,
F04.24 - Adapt DigRef
, and its basic value,
F04.25 - Adapt base value
.
ASG function is defaulted for use with Ramp reference, Speed reference or Actual speed.
These variable's scaling are 16384 counts, corresponding to the drive
B0E.00 - Full
scale speed
parameter .
This is the reason why
F04.25 - Adapt base value
parameter is defaulted to 16384
counts.
F04.25 - Adapt base value
parameter can also be changed if gain modification is driven
by some variable that has full scale different then 16384 counts. For example 4096
counts, that comes from bus or other variables present in the system.
It is possible to write an independent variable value to
F04.24 - Adapt DigRef
parameter.
N
OTE
!
The selection of base value must be done prior to assigning thresholds and bands.
After any change of
F04.25 - Adapt base value
, gains must be reassigned.
Values assigned to thresholds and bands must be in ascending order. The value
assigned to
F04.21 - Adaptive speed 1
parameter must be higher then
F04.22 -
Adaptive speed 2
parameter .
Bands must be narrower then half the distance between
F04.21 - Adaptive speed 1
and
F04.22 - Adaptive speed 2
.
When the motor is stopped, the gain of the Speed Regulator is set by the
F03.11 - Spd 0
P gain
and
F03.12 - Spd 0 I gain
, if the speed 0 function is enabled.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...