[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
ARTDrive V2 series - Instruction Manual
Chapter 6 Parameter • 263
ALARM CFG / Alarms status
Table L22-1: Alarm List table
ALARM NAME
Failure supply
Undervoltage
Overvoltage
IGBT desaturat
Inst overcurrent
Ground fault
Curr fbk loss
External fault
Spd fbk loss
Module OT
Heatsink OT
Motor OT
Heatsink S OT
Regulation S OT
Intake air S OT
ISBus fault
Comm card fault
Appl card fault
Drive overload
Motor overload
BU overload
Data lost
Fwd Rev Ctrl
Max time
Sequencer
PLS timeout
Overspeed
UV repetitive
IOC repetitive
IGBTdesat repet
WatchDog user
Hw fail
Key Em Stp fault
BIT position
in the alarm
Word
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Description (Cause of fault)
Failure of power supply
Vdc Link< UV Thr
Vdc Link> OV Thr
Too many current on output bridge
Too many current on output bridge
Output Phase discharge to ground
Loose of the reading of the current
sensor
Input pin. Programmable
Loose of the reading of the speed
sensor
Only for size <= 15kW Module
Overtemperature
Only for size > 15kW Heatsink
Overtemperature
Input Motor Overtemperature
Heatsink Overtemperature
Regulation Overtemperature
Only > 15Kw Intake air
overtemperature
Isbus card
Sbi card
Dgfc card or APC card
Reached Drive Ovld limit
Reached Motor Ovld limit
Reached BU Ovld limit
Eeprom error
Fwd and Rev both high
Exceeded max CPU time
State machine error
Power loss Stop
Actual speed > theshold with
drive running.Programmable
In 5 minutes xx UV fault occoured.
Xx progammable. If xx is set equal
to the maximum the alarm is
disable.
2 UC fault in 30 second
2 DES fault in 30 second
User Watchdog not refreshed
Loose of sincronization with
expansion or peripherals
Emergency stop by keypad
Drive activity
after Alarm
Disable drive
Disable drive
Disable drive
Disable drive
Disable drive
Programmable
Disable drive
Programmable
Programmable
Disable drive
Disable drive
Programmable
Programmable
Programmable
Programmable
Programmable
Programmable
Disable drive
Programmable
Programmable
Programmable
Disable drive
Programmable
Disable drive
Disable drive
Disable drive
Programmable
Disable drive
Disable drive
Disable drive
Disable drive
Disable drive
Disable drive
HOLD OFF
No
No
No
No
No
No
No
Yes, Program.
No
Yes Fixed 10
msec
Yes Fixed 1000
msec
Yes, Program.
Yes, Program.
Yes, Program.
Yes, Program.
No
No
No
No
No
No
No
No
No
No
No
Yes, Program.
No
No
No
No
No
No
Restart
No
Yes. logic on n°
times
Yes
Yes. logic on 2
alarms in 30
second
Yes. logic on 2
alarms in 30
second
No
No
Yes
No
No
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
No
No
Yes, Progr.
No
No
Yes, Progr.
Yes, Progr.
Yes, Progr.
Yes, Progr.
Yes, Progr.
Yes, Progr.
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Restart time
Acknowledgment
request
Msg ad alarmq
DigOut
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...