[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 196
ARTDrive V2 series - Instruction Manual
REG PARAM / DeadTime
N
OTE
!
Menu accessible with Access Level = FULL
The Dead time comp function allows for compensation of the output voltage distortion
due to IGBT voltage drop and its switching characteristics.
Distortion of output voltage may cause non uniform, non smooth shaft rotation in open
loop
V/f control
or in a closed loop
Sensorless Vector
control mode errors in speed
estimation especially at very low speeds.
Through the two parameters it is possible to set a voltage value and the compensation
variation, called Gradient.
N
OTE
!
Both parameters are automatically measured during autotune procedure.
If required, it is possible to follow a procedure that allowos to compensate the IGBT
voltage output distortion; see section 7.3, IGBT Voltage Output Distortion.
Dead time slope
i
v
Dead time limit
Voltage cmd to pwr
Output voltage
+
+
Figure E04: Dead time compensation
E04 REG PARAM / DeadTime
E04.00 Dead time limit
[V]
RWS
Calc
0.00/50
PP
V-F-S-B
Full
530
Value of the voltage compensation.
E04.01 Dead time slope
[V/A] RWS
Calc
0.00/100
PP
V-F-S-B
Full
540
Compensation Gradient.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...