Index
MENU
MENU
MENU
MENU
MENU
[Unit] Access Default
Min/Max
Format Reg.Mode Level Ipa
Parameter Name
Description
Chapter 6 Parameter • 258
ARTDrive V2 series - Instruction Manual
L13.00 ACF activity
N/A
RWS
3
2/6
DP
V-F-S-B
Full
9049
Appl card fault activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L14 ALARM CFG / Drive OL
It trips when Drive overload accumulator exceeded trip threshold.
L14.00 DOL activity
N/A
RWS
1
1/6
DP
V-F-S-B
Easy 9040
Drive overload activity:
[1] Ignore
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L15 ALARM CFG / Motor OL
It trips when Motor overload accumulator exceeded trip threshold.
L15.00 MOL activity
N/A
RWS
2
1/6
DP
V-F-S-B
Easy 9041
Motor overload activity:
[1] Ignore
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
L16 ALARM CFG / BU OL
It trips when Brake resistor overload accumulator exceeded trip threshold.
L16.00 BUOL activity
N/A
RWS
3
2/6
DP
V-F-S-B
Easy 9071
Braking Unit overload activity:
[2] Warning
[3] Disable drive
[4] Stop
[5] Fast stop
[6] Curr limstp
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...