Chapter 6 Parameter • 122
ARTDrive V2 series - Instruction Manual
B01 STARTUP / Main cmds
B01.00 Commands select
N/A
RWS
2
0/4
DV
V-F-S-B
Easy 4002
[0] TerminalLevel
The drive is controlled via terminal strip using Level sensitive signals
[1] TerminalEdge
The drive is controlled via terminal strip using Edge sensitive signals
[2] DigitalLevel
The drive is controlled from a communication or application card using level
sensitive signals
[3] DigitalEdge
The drive is controlled from a communication or application card using edge
sensitive signals
[4] I O keys
The drive is controlled from the keyboard using the I O keys; terminal 12
(Enable) to 24Vdc are required
N
OTE
!
Setting of this parameter is not allowed while terminal enable is active.
B01.01 Term Local src
N/A
RWS
Ipa4000
Plist 16
PIN
V-F-S-B
Easy 9212
Ipa 4000 - NULL = Default
It allows to select the signal to obtain the local commands by keypad.
ª
ª
ª
ª
ª
Pick List 16
Local/Remote command through digital input
The following picture shows the selection logic for the source of START and STOP
commands:
[1] Local
C
ommand
s
ou
r
c
e
s
e
l
e
cto
r C
00
-
2
0
[
2
] Digital L
e
v
e
l
[1] T
er
minal Edg
e
C
00
-43
C
00
-
0
3 = Digital input
To d
r
iv
e
command logic
[
0
] T
er
minal L
e
v
e
l
[
0
]
Re
mot
e
[3] Digital Edg
e
[4] I
O
K
e
y
s
Figure B01.01: Command selection
When the selector (dedicated digital input) is 0 (Remote),
Start
and
Stop
commands
come from the source specified by parameter
B01.00.
When the selector (dedicated digital input) is 1 (Local),
Start
and
Stop
commands come
from the keypad, regardless what is set into parameter
B01.00
.
The status of the digital selector is read by the drive only when the output of the inverter
bridge is disabled. As a result, it is not possible to switch between local and remote
source for main commands while the motor is running.
N
OTE
!
Normally the Stop key acts as Emergency stop, when the source of main
commands is not the keypad.
For more details, see P.005 parameter description below.
Summary of Contents for ARTDrive Vector V2 400Vac Series
Page 1: ...Instruction Manual ARTDrive ARTDrive Vector AC Drives V2 series 400Vac Class 575Vac Class...
Page 14: ...0 14 Chapter 0 Safety Precautions ARTDrive V2 series Instruction manual...
Page 40: ...40 Chapter 3 Installation Guidelines ARTDrive V2 series Instruction Manual...
Page 92: ...92 Chapter 5 Quick Start Up Guide ARTDrive V2 series Instruction Manual...
Page 358: ...358 Chapter 8 Appendix ARTDrive V2 series Instruction Manual...
Page 376: ...Chapter 9 Pick Lists 376 ARTDrive V2 series Instruction manual...