GEK-113032A
W650 Wind Generator Protection System
A-1
APPENDIX A
A.1 LOGIC OPERANDS
A
APPENDIX A LOGIC OPERANDSA.1LOGIC OPERANDS
OPERANDS -650 - MODEL FX - GX
INTERNAL SYSTEM STATUS
Autocheck internal states
TIMER STATUS
Real time clock autocheck
E2PROM STATUS
E2prom status :(0) Not configured or problems during
writing process ; (1) Configured and OK
GRAPHIC STATUS
Graphic display status
ALARM TEXT ARRAY
Text display status
DSP COMM ERROR
DSP communication error
MAGNETIC MODULE
ERROR
Magnetic module error
CALIBRATION ERROR
Calibration error
Other internal states
USER MAP STATUS
User map status: (0) Not configured ; (1) Configured
FACTORY
CALIBRATION
Calibration status (0) Not calibrated ; (1) Relay
calibrated
FLEXCURVE A STATUS User curve A: (0) Not configured (1) Configured
FLEXCURVE B STATUS User curve B: (0) Not configured (1) Configured
FLEXCURVE C STATUS User curve C: (0) Not configured (1) Configured
FLEXCURVE D STATUS User curve D: (0) Not configured (1) Configured
Green Zone
Memory internal status
Yellow Zone
Memory internal status
Orange Zone
Memory internal status
Red Zone
Memory internal status
UpTime
System Time
Configurable Logic Outputs (512 elements)
VIRTUAL OUTPUT 000
Configurable logic output 000
VIRTUAL OUTPUT 001
Configurable logic output 001
...
...
VIRTUAL OUTPUT 511
Configurable logic output 511
Operation Bits (24 elements)
OPERATION BIT 1
Operation bit 001: (0) the configured time expires or
when success conditions are met;(1) operation 1 is
executed and interlocks are fulfilled.
OPERATION BIT 2
Operation bit 002: (0) the configured time expires or
when success conditions are met;(1) operation 2 is
executed and interlocks are fulfilled.
...
...
OPERATION BIT 24
Operation bit 024: (0) the configured time expires or
when success conditions are met;(1) operation 24 is
executed and interlocks are fulfilled.
Control Event Bits (128 elements)
CONTROL EVENT 1
Control Event 1 Activation Bit
CONTROL EVENT 2
Control Event 2 Activation Bit
...
...
CONTROL EVENT 128
Control Event 128 Activation Bot
Latched Virtual Inputs (32 elements)
LATCHED VIRT IP 1
Latched virtual input 1
LATCHED VIRT IP 2
Latched virtual input 2
...
...
LATCHED VIRT IP 32
Latched virtual input 32
Summary of Contents for Multilin W650
Page 2: ......
Page 10: ...VIII W650 Wind Generator Protection System GEK 113032A TABLE OF CONTENTS ...
Page 30: ...1 20 W650 Wind Generator Protection System GEK 113032A 1 4 W650 HARDWARE 1 GETTING STARTED 1 ...
Page 140: ...4 72 W650 Wind Generator Protection System GEK 113032A 4 3 WEB SERVER 4 HUMAN INTERFACES 4 ...
Page 406: ...11 22 W650 Wind Generator Protection System GEK 113032A 11 15 RECLOSER 79 11 COMMISSIONING 11 ...
Page 446: ...A 22 W650 Wind Generator Protection System GEK 113032A A 1 LOGIC OPERANDS APPENDIXA A ...
Page 622: ...F 2 W650 Wind Generator Protection System GEK 113032A F 1 GE MULTILIN WARRANTY APPENDIXF F ...