Installation and Operating Manual

 

 

 

Alarm- and protection device  

 

Leak-water detector             

 

 

 

GEWAS 191 AN / N

 

 

 

 

 

Please read these instructions  
carefully before use! 

 

WEEE-Reg.-Nr. DE 93889386

 

 

Please consider the safety instructions! 

 

Please keep for future reference! 

Summary of Contents for GEWAS 191 AN

Page 1: ...Tel 49 9402 9383 0 info greisinger de www greisinger de Installation and Operating Manual Alarm and protection device Leak water detector GEWAS 191 AN N Please read these instructions carefully before use WEEE Reg Nr DE 93889386 Please consider the safety instructions Please keep for future reference ...

Page 2: ...hing machine dish washer connected to the control de vice To be able to operate safely the device has to be checked for its correct function at regular basis please refer to Operating and maintenance advices of this document Operation is only allowed with the defined scope of supply or with original accessory for this device Application range Alarm and protection device for prevention of water dam...

Page 3: ...ety may be a risk when the device has visible damages is not working as specified has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 5 Warning Do not use this product as safety or emergency stop devices or in any other applica tion were failure of the product could result in personal injury or material damag...

Page 4: ...nsor at desired position and fix it if necessary Note Choose best position for the water sensor that both metal electrodes come into contact with water as early and reliable as possible Keep an eye on floor unevenness Protect against unintended shifting e g by using a screw or mounting tape Please take care that the sensor electrodes do not touch any metallic surfaces this may cause errors Connect...

Page 5: ...ort circuiting both water sensor contacts by means of a metal object e g spoon knife etc Disconnect device and reconnect the device The solenoid has to react with a clearly audible clack sound This is to make sure that even if the water is calcareous and even if it is not regularly operated the solenoid is fully operational regard less of the calcareous deposits 5 The control device should not ope...

Page 6: ...feed 50 kPa 0 5 bar Working temperature 0 to 50 C Dimensions control unit 110 x 65 x 45 mm L x W x H solenoid valve 82 x 102 x 42 mm L x W x H Directives and standards The instruments confirm to following European Directives 2014 30 EU EMC Directive 2014 35 EU Low Voltage directive 2011 65 EU RoHS Applied harmonized standards EN 61326 1 2013 emissions level class B emi immunity according to table ...