EP OS MOTOR MANAGEMENT SY STEM – INSTRUCTION MANUAL
CHAPTER 5: WinESG
5.2
9
Table 5-1 below shows the full debug register definitions.
Element
Type
Size
Description
Notes
PMS1
Input
bit
Overload Alarm
PMS2
Input
bit
Phase loss Alarm
PMS3
Input
bit
Ground fault Alarm
PMS4
Input
bit
Unbalanced load Alarm
PMS5
Input
bit
Thermistor Alarm
PMS6
Input
bit
Emergency stop Alarm
PMS7
Input
bit
Limit switch Alarm
PMS8
Input
bit
Safety circuit Alarm
PMS9
Input
bit
Main circuit Alarm
PMS10
Input
bit
Control circuit Alarm
PMS11
Input
bit
Contactor feedbak Alarm
PMS12
Input
bit
under load current Alarm
PMS13
Input
bit
over load current Alarm
PMS14
Input
bit
External supervision Alarm
PMS15
Input
bit
Long Start Time Alarm
PMS16
Input
bit
Torque switches Alarm
PMS17
Input
bit
Device failure Alarm
PMQ1
Input
bit
Overload Manual Reset
PMQ2
Input
bit
Phase loss Manual Reset
PMQ3
Input
bit
Ground fault Manual Reset
PMQ4
Input
bit
Unbalanced load Manual Reset
PMQ5
Input
bit
Thermistor Manual Reset
PMQ6
Input
bit
Emergency stop Manual Reset
PMQ7
Input
bit
Limit switch Manual Reset
PMQ8
Input
bit
Safety circuit Manual Reset
PMQ9
Input
bit
Main circuit Manual Reset
PMQ10
Input
bit
Control circuit Manual Reset
PMQ11
Input
bit
Contactor feedbak Manual Reset
PMQ12
Input
bit
under load current Manual Reset
PMQ13
Input
bit
over load current Manual Reset
PMQ14
Input
bit
External supervision Manual Reset
PMQ15
Input
bit
Long Start Time Manual Reset
PMQ16
Input
bit
Torque switches Manual Reset
PMQ17
Input
bit
Device failure Manual Reset
PMQ18
Input
bit
Profibus Class1 failure. Manual Reset
PMQ19
Input
bit
Modbus failure. Manual Reset
PMF1
Input
bit
Default Configuration
Use on motor starter typicals only
PMF2
Input
bit
Disable alarm underload current
Use on motor starter typicals only
PMF3
Input
bit
Disable alarm overload current
Use on motor starter typicals only
PMF4
Input
bit
Accept parameterization mode
Use on motor starter typicals only
PMF5
Input
bit
Reserved
PMF6
Input
bit
Ignore Phase loss during start phase
Use on motor starter typicals only
PMF7
Input
bit
Ignore earth fault during start phase
Use on motor starter typicals only
PMF8
Input
bit
Ignore Unbalance load during start phase
Use on motor starter typicals only
PMF9
Input
bit
Motor Starter Typical selection
Use on motor starter typicals only
PMF10
Input
bit
Reserved
PMF11
Input
bit
Reserved
PMF12
Input
bit
Reserved
PMF13
Input
bit
Control mode variant selection
Use on motor starter typicals only
PMF14
Input
bit
Reserved
PMF15
Input
bit
Reserved
PMF16
Input
bit
Reserved
DI 11
Input
bit
Input 11 State
DI 12
Input
bit
Input 12 State