1.
Auxiliary O2, 0-10 l/min (optional)
45.
Inspiratory flow sensor
2.
241 kPa (35 psi) secondary O2 regulator
46.
Patient wye (patient connection)
3.
Pipeline: O2, Air, N2O
47.
Airway transducer
4.
Cylinder: O1, Air, N2O
48.
Inspiratory flow transducer
5.
758 kPa (110 psi) relief
49.
Expiratory flow transducer
6.
Venturi drive gas connection
50.
Manifold pressure transducer
7.
Selector valve, O2, Air, N2O
51.
Passive gas scavenging interface
8.
O2 flush
52.
30 mm male to disposal system
9.
0-120 l/min flow
53.
0.3 cmH2O entrainment
10.
Alternate O2
54.
Reservoir
11.
System switch
55.
Adjustable gas scavenging interface
12.
Alternate O2 disable valve
56.
DISS EVAC connector
13.
ACGO/non-circle port
57.
Active gas scavenging interface
14.
Vent drive gas select
58.
Room air
15.
O2 flow controller
59.
Filter
16.
Balance flow controller
60.
High or low flow restrictor
17.
Gas inlet valve
61.
Flow indicator
18.
Vent drive gas regulator 172 kPa (25 psi) at 15
l/min
62.
To disposal system
19.
Inspiratory flow control valve
63.
ACGO variant
20.
Drive gas check valve (3.5 cmH2O bias)
64.
Circle or ACGO mode switch
21.
Mechanical over pressure valve (110 cmH2O)
65.
22 mm ACGO port
22.
Free breathing check valve
66.
O2 cell
23.
Atmosphere
67.
Non-circle variant
24.
Pressure relief valve
68.
Circle or non-circle mode switch
25.
Exhalation valve (2 cmH2O bias)
69.
Non-circle circuit pressure limiting valve
26.
Relief valve 10 cmH2O
70.
Bag/Vent switch
27.
0-10 l/min drive gas, 0-10 l/min patient and fresh
gas, 0-10 l/min total typical flow
71.
Bag
28.
200 ml reservoir
72.
APL valve 0-70 cmH2O
29.
Control bleed to ambient approximately 1 l/min at 3
cmH2O if continuous (rate dependent)
73.
Default factory connection
30.
Vent to ambient
74.
Gas monitor
31.
Flush switch 37.2 kPa (5.4 psi)
75.
Negative pressure relief valve
32.
Electronic vaporizer
76.
Absorber
33.
ACGO port relief valve
77.
Drain
34.
Cassette inflow measure
78.
EZchange canister
35.
Cassette inflow valve
79.
Condenser
36.
Cassette identification
80.
Bypass back-pressure valve
37.
Cassette outflow measure
81.
Inflow check valve
38.
Cassette flow control valve
82.
Cassette pressure sensor
39.
Liquid flow prevention valve
83.
Cassette connection valve
40.
Cassette outflow valve
84.
Aladin cassette
41.
Scavenging valve
85.
Pneumatic power outlet
42.
Cassette temperature sensor
86.
Embedded temperature sensor (not available on all
cassettes)
43.
Liquid level indicator (not available on all cassettes) 87.
Fresh gas sample relief valve
44.
Expiratory flow sensor
11 Specifications and theory of operation
2067226-001
11-3
Summary of Contents for auisys cs2
Page 1: ...Aisys CS User s Reference Manual Software Revision 10 X ...
Page 32: ...1 20 2067226 001 ...
Page 60: ...3 Set the alarm limits to clinically appropriate settings Aisys CS 3 12 2067226 001 ...
Page 87: ...3 Push the drain button to empty any water in the condenser 3 Operation 2067226 001 3 39 ...
Page 90: ...3 42 2067226 001 ...
Page 94: ...4 4 2067226 001 ...
Page 132: ...7 20 2067226 001 ...
Page 164: ...9 8 2067226 001 ...
Page 178: ...System pneumatic circuit AB 75 270 Aisys CS 11 2 2067226 001 ...
Page 230: ...4 Select Back to return to the Gas Usage menu Aisys CS 12 4 2067226 001 ...
Page 262: ...13 20 2067226 001 ...
Page 268: ...Aisys CS User s Reference Manual English 2067226 001 06 13 C 18 05 02 Printed in USA ...