CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.15.1
Chapter 15: Setting up the CS7050
15.1 Overview
The CS7050 TCP/IP module is a dual microprocessor-controlled Internet/Intranet interface used to connect the
CSx75 control panel to the OH Network Receiver. This interface allows any or all events from the CSx75 to be
reported over the network. The CS7050 TCP/IP module features include:
•
Four programmable report destinations (two TCP/IP receivers, two email addresses).
•
Event reporting from eight partitions.
•
Selectable reportable events for each partition.
•
Control panel as backup.
•
SIA reporting using TCP/IP.
•
Contact ID reporting using TCP/IP.
•
Email reporting in English and on POP server only.
•
DHCP or fixed IP address.
•
Upload/download may be initiated remotely or locally.
•
Optional automatic download sessions. These normally follow test calls. Test call reporting can be switched
off so that there is automatic download calls without test report calls.
15.2 Installing the CS7050 TCP/IP module
For information on installing the CS7050 TCP/IP module in the various housings, see chapter A-4
Installing a
basic system
.
1
SIM pin 1
5
RS232
2
Modem pin 2
6
Connect to CSx75 panel
3
Processor to RS232 setting: position 9 &10
7
10BT ethernet
4
Processor to RS232 setting: position 3 & 4
8
Audio tap
1
2
3
4
5
6
7