CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.2.23
2.4.4.2.1
Tamper/Trouble
A menu entry that groups together the tamper and trouble events that are
reported to the central station.
2.4.4.2.1.1
Box Tamper
A menu option that enables the box tamper switch on the control panel. The
CSx75 has an input for a normally closed tamper switch. When opened, a box
tamper is reported as an event.
2.4.4.2.1.2
Expander Trouble
A menu option that sends a report to the central station when an expander
trouble condition occurs.
2.4.4.2.1.3
Siren Supervision
A menu option that monitors the siren to detect cut wires. If the wires are cut,
the control panel sends a report to the central station.
2.4.4.2.1.4
RF Sensor Lost
A menu option that sends a report to the central station, when an RF sensor is
missing.
RF sensors send out supervision signals every 15 or 64 minutes, depending
on the frequency. An RF receiver must receive these signals within a specified
time window. This window is set by the Supervision timer. If the RF receiver
does not receive these signals during the time window, the RF sensor is
considered missing.
2.4.4.2.1.5
RF Low Battery
A menu option that sends a report to the central station when a low battery
condition occurs in an RF sensor.
2.4.4.2.2
Power
A menu entry that groups the power events that are reported to the central
station.
2.4.4.2.2.1
Mains Failure
A menu option that sends a report to the central station when the mains power
supply fails. A delay time can be set for this report.
2.4.4.2.2.2
Low Battery
A menu option that enables low battery reporting on the control panel.
2.4.4.2.2.3
Aux Overcurrent
A menu option that enables overcurrent reporting. A report is sent to the
selected central station when too much current is drawn from a device
powered by the system.
2.4.4.2.3
Communications
A menu entry that groups together the communication events that are reported
to the central station.
2.4.4.2.3.1
Phone Line Cut
A menu option that sends a report is sent to the central station the moment the
phone line cut is restored.
2.4.4.2.3.2
Fail to Communicate
A menu option that sends a report to the central station when the system has
failed to communicate with the central station after the number of attempts set
in FTC Dialler Attempts. The report is sent when communication with the
central station has been restored.
2.4.4.2.3.3
Autotest
A menu option that enables reporting of autotest events to the central station
at a specified interval.
2.4.4.2.3.4
Autotest Disarmed No Call
A menu option that allows test calls to be made only when the system is
armed.
2.4.4.2.4.1
Log Full
A menu option that sends a report to the central station when the event log is
full.
2.4.4.2.4.2
Start/End Programming
A menu option that causes reports to be sent to a specified phone number. A
report is sent when local programming begins and ends.
2.4.4.2.4.3
End Download
A menu option that sends a report to the central station when downloading
from the up/download software to the control panel is complete.
2.4.4.2.5
Bypass on Force Arm
A menu option that enables bypass reporting when a zone is force armed.
Location
Term
Definition