CS875-575-375-275-175 Installers Manual with CS5500 keypad
B.13.7
13.4 Glossary
Location
Term
Definition
13
CS7002 GPRS Module
A module that operates as a GPRS and GSM communications module for
reporting and upload/download.
13.1
Reporting
A menu entry that groups reporting options.
13.1.1
Report Control
A block of reporting data that contains configurations to format selected events
into one or more messages according to pre-configured settings and send
them to specified destinations.
A menu entry that groups report control options.
13.1.1.1.1
Destination
A menu option that configures the report destination for the selected report
control.
13.1.1.1.2
Backup Destination
A menu option that configures the backup destination for the selected report
control. If using another device as the backup destination, set the reporting
format in Reporting>Backup Format and enable test report events in the
backup device.
13.1.1.1.3
Events
A menu entry that contains all configurable events for each report control. All
events for report control 1 are enabled by default. Events for all other report
controls are disabled by default. Enabled events are formatted into one or
more messages according to pre-configured settings and sent to the selected
report destination. You must enable only Test Reports if using the CS7002 as
backup to another auxiliary dialler.
13.1.1.1.3.1
Arm/Disarm/Alarm
A menu entry that groups the events that are reported to the selected report
control.
13.1.1.1.3.1.1
Alarms
A menu option that sends a report to the selected report control when an alarm
occurs.
13.1.1.1.3.1.2
Alarm Restores
A menu option that sends a report to the selected report control when the
alarm has been restored after an alarm.
13.1.1.1.3.1.3
Opening/Closings
A menu option that sends a report to the selected report control stating when
the system is opened (disarmed) and closed (armed).
13.1.1.1.3.1.4
Zone Bypass and Restores
A menu option that sends a report to the selected report control when a zone is
bypassed. A report is also sent when the zone is restored (un-bypassed).
13.1.1.1.3.2
Tamper/Trouble
A menu entry that groups together the tamper and trouble events that are
reported to the selected report control.
13.1.1.1.3.2.1
Tampers and Restores
A menu option that sends a report to the selected report control when a tamper
occurs. A report is also sent when the tamper is no longer active.
13.1.1.1.3.2.2
Zone Trouble and Restores
A menu option that sends a report to the selected report control when a zone
trouble condition occurs. A report is also sent when the trouble condition is no
longer active.
13.1.1.1.3.2.3
Expander Trouble and Restores
A menu option that sends an expander trouble and restore report to the
selected report control.
13.1.1.1.3.2.4
Siren/Phone Faults and Restores
A menu option that sends a report to the selected report control when a siren
or phone fault occurs. A restore report is sent when the fault is fixed.
13.1.1.1.3.2.5
RF Sensor Lost and Restores
A menu option that sends a report to the selected report control when an RF
sensor is missing. A restore report is sent to the central station when the
receiver receives a valid signal from the lost transmitter.
13.1.1.1.3.2.6
RF Low Battery and Restores
A menu option that sends a report to the selected report control when a low
battery condition occurs in an RF sensor. A restore report is also sent when the
low battery condition is no longer active.